If errors in the validation panel occur, try clearing the compiler cache. This could always helpful to resolve displayed compiler errors. If you still meet errors during compilation or deployment after clearing the cache, export the Support Data and attach it to your support request. You find both options in the additional menu of the Controls panel. The following table can be searched. Enter your search term in the Global Filter field. Oops, it seems that you need to place a table or a macro generating a table within the Table Filter macro. The table is being loaded. Please wait for a bit ... [VALXUML] error Contact the PAS support team and attach the Designer service. An error has occurred during the compilation of the project An error has occurred during the project data preparation This error is shown if the code preparing the zip file for the compiler encounters an error. An error has occurred during the project data preparation: Project data may be corrupt This error is shown if an import file contains corrupt data. javax.ws.rs.ProcessingException: java.io.IOException: Error writing to server REST interface classes: urn.AddressImplementation.Address.Public.Address, urn. Data_Model.com.Address share common class name 'Address' but class names in REST interface must be unique. Your BPMN model name (in our example: Address ) and a class of a BPMN message (in our example com.Address ) have the same name. Rename the BPMN or message class. Version of the project ('21.2') is not compliant with semver format (major.minor.patch). Change the version number of your service. The number must follow Semantic Versioning 2.0.0: Major.Minor.Patch. A pre-release tag is optional. If the deployment from within the Designer keeps running into a timeout, you can try to deploy the compiled service directly in the integration component (Bridge). Open the additional menu of the Controls panel and select the export option Compiled > Service. This will download a file in .rep format. In the next step, you can define if the service should be started automatically after deployment. Click Deploy to start the deployment process. You will get a notification message when the deployment has been finished. For more information on deploying xUML service repositories to the Integration (Bridge) and explanations on all options, refer to Deployment of xUML Services. Go back to the Designer and reload the browser tab. Check the Controls panel to see if the service is running: The icons to stop the service and to open the application should now be enabled.Validation Panel Messages
Validation Panel Message Possible Reason Solution Further Information The compiler receives data he cannot process. This error is shown if the communication with the compiler failed.
The deployment took to long and ran in a timeout. There are duplicate class names in your model. The version number of your service is not written in the correct notation. Deploying a Service to the Integration Component
Open the PAS integration component (Bridge). Select the menu option Deployment and choose the exported .rep file of your service for upload.
- No labels