On this Page:
The following picture shows the usage of the <<Logger>> adapter:
Tag action of the logger adapter needs to be set to log. The following input can be provided:
Object Name | Type | Description | Allowed Values / Example | |
---|---|---|---|---|
level | String | Specify one of the error log levels described in the log level guidelines on Bridge Server Log Levels of an xUML Service. | One of Fatal, Error, Warning, Info, and Debug. | |
type | String | Specify a custom error domain. | Stock_Synchronization | |
code | String | Specify a custom error code. |
| |
description | String | Specify a description for the log entry. | Item ID could not be found. | |
details | Any | Runtime 2020.6 Builder 7.8.0 Specify an object of complex type (class or array) that contains additional details. The contents of this object will be flattened and appended to the description. | an error detail object |
Example
Pin | Value |
---|---|
level | Error |
type | Stock_Synchronization |
code | SYNC001 |
description | Item ID could not be found. |
details |
|
The output after running the example can be found in the standard xUML service log of the xUML service:
...[Error][Internal][Stock_Synchronization][Item ID could not be found. Detail: e2e:type='ErrorDetail', element='AF-1201', value='Adapter']
In case of an array, the output would look something like:
... Detail: e2e:type='ErrorDetail', [0].element='
AF-1201
', [0].value='Adapter
', [1].element='CD-2000
', [1].value='Connector
'